LanguageENESPT
Quality & purchasing · Nov 2026

Sampling and retained samples when a black masterbatch delivery is questioned

When a delivery is questioned, the sample is the evidence. A disagreement about gels, colour or flow is hard to settle if nobody kept a sample that both sides can identify.

By Zoe Lin, Export Manager, E-LUCK

This is a buyer-side purchasing control, not a standard sampling procedure and not a laboratory certification. Before any split or test, agree the sampling purpose, representativeness, who takes the sample, how many parts are kept and how contamination and moisture uptake are avoided.

1. Sample from the lot you received

Record the order line, bag label and lot identifier before opening bags. Where the lot is in several bags and the parties agree that a multi-bag sample is appropriate, take material from more than one bag and keep the bag labels with the sample. A limited sample may not represent the whole lot; agree a sampling plan appropriate to the purpose before drawing a lot-wide conclusion. A sample without a lot reference is not evidence about that lot. The incoming-record article shows the four rows to write down first.

2. Split the sample and label each part

Keep one sealed part as a retained reference and send another for testing, only after the split and the number of parts have been agreed with the supplier. Label each part with the supplier, grade, lot, date, sampler and seal reference. Use a clean, dry container; do not mix lots. Agree the sample split with the supplier if a claim may follow.

3. Agree the method before the test

A result means little without a stated method, conditions and scope. For melt flow, state temperature and load. For carbon black content, state the method and its applicable polymer/filler range. For dispersion, name the method (for example filter pressure value or microscopic rating), the test conditions and the let-down ratio used. A filter pressure value is a dispersibility result, not a carbon black content figure. A CoA describes the lot or sample it identifies and should not be extended beyond that scope; a separate laboratory report applies to the sample and scope it identifies. Published SGS test reports state the samples and scope they cover.

4. Keep a chain of custody

Write who held the sample, when it was sealed, when it was handed over and to whom. Photograph the seal and the bag labels. Keep documents with the sample. If a claim is raised weeks later, this record shows what was sampled and how it was handled; the test result and the record serve different purposes.

5. What the routine does not establish

Sampling and retention do not by themselves prove carbon black content, moisture or dispersion. Those need an agreed method, a sample and a result. They also do not assign responsibility: a test result applies to the sample under the conditions used, and a buyer and supplier should agree in writing how the sample was taken and which method applies before testing starts.

6. Put the terms into the purchase order

Before placing an order, add the sampling and retention terms to the purchase order: who takes the sample, how many parts, how they are labelled, which method is used and how long the retained part is kept.

A retained-sample record you can use

Use this blank record with the sampling plan agreed for your order. Print it or download the editable CSV record. It records what was done; it does not choose a sample size, set a retention period or establish a test result.

Buyer and supplier record — complete the empty cells together
RecordAgreed details
Order and material
Purchase order / order line; supplier; grade; lot; bag labels
 
Sampling basis
Purpose; agreed plan; bags or locations sampled; any limitation
 
Drawing the sample
Date and time; sampler; container; condition observed
 
Split and seals
Part identifiers; amount in each part; seal references; recipients
 
Custody
Handover date; sender; receiver; seal condition on arrival
 
Test request
Property; method and edition; conditions; lab; acceptance criterion if agreed
 
Retention and changes
Storage conditions; agreed retain-until date; owner; any exception or later opening
 

Keep separate records for separate lots. If an item is unknown, mark it as unknown and state how it will be resolved; do not fill a gap with an assumed result. Before releasing a sample, match its label to the order, the seal and the requested method.

For a quotation, attach the agreed record or describe the missing item in the grade and document enquiry. Sampling, testing, sample supply and CoA terms are confirmed for the specific enquiry.

Continue reading

Sources and method scope

The sampling and retained-sample practice described here is a buyer-side recommendation for commercial records. It is not a standard sampling procedure and it does not certify any measurement.

Need this in a quotation for a specific grade and lot? Send three numbers — your polymer, your target carbon black content or let-down, and your monthly volume — using the quote and document request. We work out the rest together.

Questions buyers ask

Is taking a sample the same as testing the material?

No. Sampling and retention do not by themselves prove carbon black content, moisture or dispersion. Those need an agreed method, a sample and a result.

Can a few bags represent a whole lot?

A limited sample may not represent the whole lot; agree a sampling plan appropriate to the purpose before drawing a lot-wide conclusion.

When should the sample be split and sent for testing?

Keep one sealed part as a retained reference and send another for testing, only after the split and the number of parts have been agreed with the supplier.

Does a filter pressure value give the carbon black content?

No. A filter pressure value is a dispersibility result, not a carbon black content figure.

What should be recorded so a sample can be traced later?

Label each part with the supplier, grade, lot, date, sampler and seal reference, and keep a chain of custody: who held it, when it was sealed, when it was handed over and to whom.